TM 5-3820-276-10-2
0225
WINTERIZE GROUTER - Continued
2
3
1
4
5
6
7
WWDS00350
Figure 23. Cycling Propylene Glycol.
11.
Pull GROUT PUMP flow divider lever (Figure 23, Item 1) down to OFF position after allowing propylene
glycol to cycle through.
12.
Set THROTTLE CONTROL (Figure 23, Item 4) switch to OFF position.
13.
Rotate key (Figure 23, Item 3) to Off (O) position.
14.
Close control panel door (Figure 23, Item 2) and secure with latch (Figure 23, Item 5).
15.
Set Grout Pump Auto switch (Figure 23, Item 6) to OFF position.
CAUTION
Make sure ball valves are not left fully open or closed. Water can get trapped behind ball
housing causing it to freeze and break. Failure to comply may result in damage to
equipment.
16.
Close main grout valve (Figure 23, Item 7) half way.
END OF TASK
0225-25