• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. PMCS - WWDR - Before Road and Towing Operation - Continued
Table 1. PMCS - WWDR - Before Road and Towing Operation - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  346    347    348    349    350  351  352    353    354    355    356  
img
. .
TM 5-3820-276-10-2
0198
Table 1.
PMCS - WWDR - Before Road and Towing Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
NOTE
Drain fuel into suitable container.
Operating vehicle with damaged
fuel/water separator may violate
AR 38555 (WP 0230).
1. Check fuel/water separator (Figure 3, Item 1) for
Any evidence of leaks.
leaks.
Notify maintenance.
1
2
3
WWDS00881
Figure 3.
Fuel/Water Separator.
2. Check for presence of water in bowl (Figure 3, Item
2) of fuel/water separator (Figure 3, Item 1). If there is
any water in bowl, perform the following steps:
a. Put a suitable container under knurled nut
(Figure 3, Item 3).
b. Turn knurled nut (Figure 3, Item 3)
counterclockwise to open drain valve.
c. Drain until only pure fuel is coming out.
d. Close drain valve by turning knurled nut (Figure
3, Item 3) clockwise.
e. Dispose of fuel per local policy.
5
Before
Air Tank Drain
Check air tank drain valves (Figure 4, Item 1) for
Valves damaged or levers
Valves
damaged valves or broken levers. Air Tank Drain
will not open valves.
Notify maintenance.
0198-4
02/13/2013root(pmcswp)wpno(I10001)


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.