Table 1. Compressor Fault Codes - Continued
FOUR DIGIT MALFUNCTION CODE DISPLAY WILL NOT ILLUMINATE - PORTABLE AIR COMPRESSOR (PAC)

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  279    280    281    282    283  284  285    286    287    288    289  
img
. . . . .
TM 5-3820-276-10-2
0178
COMPRESSOR FAULT CODE RETRIEVAL AND SYMPTOM INDEX - PORTABLE AIR COMPRESSOR (PAC)
- Continued
CORRECTIVE ACTION - Continued
Table 1.
Compressor Fault Codes - Continued.
SHUTDOWN
FAULT
COMPRESSOR
SHUTDOWN
DELAY
CORRECTIVE ACTION
CODE
FAULT CODE
CONDITION
(seconds)
Low Battery Voltage
No
Refer to Battery Voltage
Low troubleshooting
procedure. (WP 0187)
Low Engine Oil
No
Refer to Engine Has Low
Pressure
Oil Pressure. (WP 0186)
Low Coolant Level
No
Service with engine
coolant. (WP 0201)
High Engine Coolant
Yes
10
Refer to Engine Has High
Temp
Temperature. (WP 0185)
IQ Filter Restriction
Yes
3
Notify maintenance.
High Discharge
Yes
3
Refer to High Compressor
Temp (RT2 > 247F)
Discharge Temperature.
(WP 0188)
a.
If compressor problem is resolved, return to normal operation.
b.
If compressor problem is not resolved and requires further diagnosis, notify maintenance.
END OF WORK PACKAGE