Table 1. Compressor Fault Codes
Table 1. Compressor Fault Codes - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  278    279    280    281    282  283  284    285    286    287    288  
img
.
TM 5-3820-276-10-2
0178
COMPRESSOR FAULT CODE RETRIEVAL AND SYMPTOM INDEX - PORTABLE AIR COMPRESSOR (PAC)
- Continued
CORRECTIVE ACTION - Continued
Table 1.
Compressor Fault Codes - Continued.
SHUTDOWN
FAULT
COMPRESSOR
SHUTDOWN
DELAY
CORRECTIVE ACTION
CODE
FAULT CODE
CONDITION
(seconds)
Machine Over
Yes
1
Notify maintenance.
35
Pressure
36
Safety Valve Open
Yes
2
Notify maintenance.
50
Separator Tank
Yes
3
Check for air inlet
Temp > 247F
restrictions. Check for dirty
or clogged coolers. Notify
maintenance.
51
Machine ID Not Valid
Yes
0
Notify maintenance.
Sep. Tank Temp
Yes
10
Notify maintenance.
53
(RT1) Sensor Fault
54
Reg. System
No
Notify maintenance.
Pressure (PT2)
Sensor Fault
56
Minimum Pressure
No
Verify engine speed has
Not Met
increased to 1800 RPM
when service discharge
switch is pressed. Notify
maintenance.
Serial
No
Notify maintenance.
70
Communication
Problem
71
CAN Bus Problem
No
Notify maintenance.
Auto Start/Stop
No
Notify maintenance.
Module Failure - No
73
Communication for
17 seconds
Low Fuel Level
No
Service with fuel. (Volume
1, WP 0056)
Air Filter Restriction
No
Clean air filters and/or
remove restriction.
(WP 0214)
0178-6