• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
CHAPTER 5. TROUBLESHOOTING PROCEDURES - MCS MUD CLEANING SYSTEM (MCS)
ENGINE CRANKS BUT DOES NOT START - MCS - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  239    240    241    242    243  244  245    246    247    248    249  
img
. . . . . .
TM 5-3820-276-10-2
0166
OPERATOR MAINTENANCE
ENGINE CRANKS BUT DOES NOT START - MUD CLEANING SYSTEM (MCS)
INITIAL SETUP:
References
Equipment Condition
Volume 1, WP 0051
Engine off (Volume 1, WP 0050)
WP 0171
WP 0220
TROUBLESHOOTING PROCEDURE
ENGINE CRANKS BUT DOES NOT START - MCS
SYMPTOM
Engine cranks but will not start.
MALFUNCTION
Low fuel.
CORRECTIVE ACTION
Inspect fuel level (Volume 1, WP 0051).
a.
If fuel level is at or below E, fill fuel tank to at least 1/4 full (Volume 1, WP 0051).
b.
If fuel level is 1/4 tank or more, proceed to next MALFUNCTION - Air filter clogged.
MALFUNCTION
Air filter clogged.
CORRECTIVE ACTION
Inspect air filter (WP 0220).
a.
If air filter needs servicing, service air filter (WP 0220).
b.
If air filter does not need servicing, proceed to next MALFUNCTION - Fault alarm present.
MALFUNCTION
Fault alarm present.
CORRECTIVE ACTION
Verify if fault alarms are present (WP 0171).
a.
If fault alarms are present, note what alarms are present and notify maintenance.
0166-1
02/13/2013root(tswp)wpno(T40001)