• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 4. Hydraulic Oil Sight/Temperature Gauge.
WATER PUMP IS NOISY DURING OPERATION - WATER WELL SUPPORT VEHICLE (WWSV)

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
TM 5-3820-276-10-2
0137
TRUCK-MOUNTED CRANE DOES NOT OPERATE PROPERLY - WWSV - Continued
CORRECTIVE ACTION - Continued
MALFUNCTION
Crane controller antenna damaged, loose, or disconnected.
CORRECTIVE ACTION
WARNING
The Water Well Drilling System presents numerous falling hazards. Use care
when working on top of equipment. Failure to comply may result in injury or death
to personnel. Seek medical attention in the event of an injury.
Verify if crane controller antenna is damaged, loose, or disconnected (Volume 1, WP 0034).
a.
If crane controller antenna is damaged, notify maintenance.
b.
If crane controller antenna is loose or disconnected, securely connect antenna to crane
controller. Verify if crane operates using remote control (Volume 1, WP 0034).
c.
If crane controller antenna is not damaged, loose, or disconnected, proceed to next
MALFUNCTION - Remote control outside of receiving range of controller.
MALFUNCTION
Remote control outside of receiving range of controller.
CORRECTIVE ACTION
Attempt to operate crane using remote control with remote control within 10 feet of vehicle
(Volume 1, WP 0034).
a.
If crane operates, problem solved.
b.
If crane does not operate, notify maintenance.
END OF WORK PACKAGE