EMERGENCY SHUTDOWN OF THE MUD CLEANING SYSTEM - Continued
EMERGENCY SHUTDOWN OF MCS APU - Continued

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  703    704    705    706    707  708  709    710    711    712    713  
img
. . .
//////////////////////////////////////////////////////////////////////////////////////////////////////////////
TM 5-3820-276-10-1
0071
OPERATOR MAINTENANCE
EMERGENCY SHUTDOWN PROCEDURES - MUD CLEANING SYSTEM (MCS) AUXILIARY POWER UNIT
(APU)
INITIAL SETUP:
Equipment Condition
APU on (WP 0054)
EMERGENCY SHUTDOWN OF MCS APU
NOTE
APU EMERGENCY STOP button shuts off APU output power only. APU and Mud
Cleaning System continue to run after EMERGENCY STOP button is pushed in.
1.
Push EMERGENCY STOP button (Figure 1, Item 6) in to stop APU.
1
2
3
6
5
4
WWDS00067
Figure 1.
APU Emergency Stop Button.
2.
Rotate two enclosure knobs (Figure 1, Item 5) to open control panel door (Figure 1, Item 4).
3.
Rotate GENERATOR switch (Figure 1, Item 1) to OFF position.
0071-1