AUTOMATIC GROUTER OPERATION - Continued
Figure 6. Shutdown

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  476    477    478    479    480  481  482    483    484    485    486  
img
.
TM 5-3820-276-10-1
0040
MANUAL GROUT PUMP OPERATION
1.
Perform grouter Starting Procedure.
NOTE
Grout Pump Auto switch must be off to operate Grout Pump Manual switch.
2.
Set Grout Pump Auto switch (Figure 5, Item 2) down to OFF position.
1
2
3
WWDS00768
Figure 5.
Manual Pump Operation.
3.
Set Grout Pump Manual switch (Figure 5, Item 3) up or down as required, to manually move pump pistons.
4.
Set Grout Pump Auto switch (Figure 5, Item 2) up to ON position.
5.
Pull Grout Pump flow divider valve lever (Figure 5, Item 1) to UP MAX. position to desired flow.
6.
Perform Shutdown Procedure.
END OF TASK
0040-5