TM 10-4630-207-13&P
0017 00
Table 4. Tank not loading.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Tank not loading.
Step 1. Perform Procedure 3 as
Step 2. Perform Procedure 6 as
Replace any malfunctioning
hydraulic component(s) as
Step 3. Check operation of intake
Remove obstruction in intake
valve (1) WP 0005 00. Determine
valve. Replace an intake valve, if
if valve is obstructed and will not
required, as described in WP
open and close completely.
Step 4. Check operation of ball
Replace a ball valve, if required,
valve (2) on chopper tube/wand.
Determine if valve is obstructed
Clear obstruction.
and won't open/close completely.
Step 5. Ensure moisture trap (3)
Open drain on moisture trap and
is drained and free of material.
let drain. Clean or replace the
Examine sight glass (4) for
moisture trap as described in WP
evidence of clogging.
Step 6. Ensure isolation valve (5)
Pull valve handle down. Replace
is fully open. Check primary
primary shutoff as described in
shutoff (6) float ball for free
movement.
1
2
3
5
4
6
0017 00-5