TM 10-4630-206-12&P
0019 00
Replace the Pump (9-1-0527)
WARNING
Ensure that the SEP has been thoroughly cleaned with chlorine
solution and rinsed prior to any inspection or service to the interior.
Failure to do so may result in serious injury or death to personnel.
WARNING
The site power must be disconnected before proceeding further.
Touching a live wire can cause serious injury or death to personnel.
1. Tag and disconnect the pump wiring (1) from the terminal board (2).
2. Remove the access panel.
3. Loosen the pump power cord bushings (3).
4. Pull the pump power cord through the bushings.
5. Remove the check valve connection (4).
6. Remove the two wingnuts on the pump bracket (5).
7. Remove the bracket.
8. Remove the pump (6).
9. Remove the discharge hose (7) from the pump.
10. Install the discharge hose on the replacement pump.
11. Install the replacement pump.
12. Reinstall the pump bracket (5) and secure with wingnuts.
13. Reinstall the check valve connection (4).
14. Feed the pump power cord through the pump power cord bushings (3).
15. Connect the pump power cord to the terminal board (2).
16. Tighten the pump power cord bushings.
17. Reinstall the access panel.
18. Check for proper operation.
0019 00-5