TM 10-4630-206-12&P
0020 00
4. Disconnect the interior discharge hose (4) from the pump discharge.
5. Loosen the power cord tank bushing.
WARNING
The site power must be disconnected before proceeding further.
Touching a live wire can cause serious injury or death.
6. Disconnect the power cord (5) from the contactor.
7. Remove the pump (6) from the SEP (7).
8. Locate the oil fill plug (8) in the top of the pump motor.
9. Remove oil fill plug and drain oil.
10. Remove bolts (9) from capacitor housing (10).
11. Lift housing.
12. Remove rubber seal ring (11).
13. Disconnect and tag cord leads.
14. Remove ground screw (12).
15. Unscrew cord bushing (13) from housing.
16. Remove power cord from housing.
17. Install new cord bushing (13).
18. Install ground screw (12).
19. Reconnect cord leads.
20. Install new rubber seal ring (11).
21. Install capacitor housing (10).
22. Refill with new oil to one-inch from top of capacitor housing (approximately 2-quarts).
23. Install oil fill plug (8).
24. Install pump (6) in SEP tank (7).
25. Install the internal discharge hose (4).
0020 00-2