TM 10-4630-206-12&P
UNIT MAINTENANCE
SEWAGE EJECTION PUMP, LAUNDRY
NSN 4630-01-413-2606
SEWAGE EJECTION PUMP, GENERAL PURPOSE
NSN 4630-01-413-2608
PUMP POWER CORD
REPLACE
INITIAL SETUP
Tools
Personnel Required
Electrician
Tool Kit, General Mechanics Automotive (Item 3, WP 0025 00)
Materials/Parts
Equipment Condition
Disconnect site power
All circuit breakers set to OFF
Tank empty
REPLACE
Replace the Pump Power Cord
WARNING
Ensure the SEP has been thoroughly cleaned with chlorine solution
and rinsed prior to any inspection or service to the interior. Failure
to do so may result in serious illness or death to personnel.
1. Remove tank lid.
2. Remove the eyebolt (1) from the cross brace (2).
3. Remove the cross brace (2) and spacer (3).
4
1
2