TM 10-4630-206-12&P
0019 00
NOTE
Proceed with steps 7 through 21 only if the replacement pump does
not have a power cord.
8. Locate the oil fill plug (8) in the top of the pump motor.
9. Remove oil fill plug and drain oil.
10. Remove bolts (9) from capacitor housing (10). Lift housing.
11. Remove rubber seal ring (11).
12. Disconnect and tag cord leads.
13. Remove ground screw (12).
14. Unscrew cord bushing (13) from housing.
15. Remove power cord from housing.
16. Install new cord bushing (13).
17. Install ground screw (12).
18. Reconnect cord leads.
19. Install new rubber seal ring (11).
20. Install capacitor housing (10).
21. Refill with new oil to one-inch from top of capacitor housing (approximately 2-quarts).
22. Install oil fill plug (8).
23. Install pump (6) in SEP tank (7).
24. Install power cord at contactor as tagged.
25. Tighten the power cord tank bushing.
26. Install the internal discharge hose (4).
27. Install the spacer (3), cross brace (2) and eyebolt (1).
28. Install the tank lid.
29. Test for proper operation.
0019 00-2