2.15.8 Power Control Cable Assembly Maintenance, Model 609-A.
This task covers:
2.15.8.1 Removal
2.15.8.3 Adjustment
2 .
15 . 8 . 2 I n s t a l l a t i on
INITIAL SETUP
Tools
General Mechanics Automotive
Tool Kit, Appendix B, Section
III, Item 1
Material/Parts
Lock Washers (TM 10-4320-344-24P)
Equipment Conditions
Pumping station shut down, TM
10-4320-344-10.
Equipment Conditions (Continued)
Battery disconnected, paragraph 2.15.2.
General Safety Instructions
To prevent rolling or sliding, do not work
on equipment that is not securely
s t a b i l i z e d .
Do not work on equipment with battery
connected.
Electrocution hazard is present
if battery is connected.
Do not work on equipment without following
standard shop safety precautions.
2.15.8.1 Removal.
a .
b .
c .
d.
e .
Do not work on equipment with battery connected.
present if battery is connected. Failure to obey
death or serious personal injury.
Loosen screw (Figure 2-44, 1) on universal wire
wire stop (2) from power control cable assembly
Loosen screw (4) and remove universal wire stop
Electrocution hazard is
this warning may result in
stop (2) and remove universal
( 3 ) .
(5) from wire (6).
Remove nut (7) and lock washer (8) from end of power control cable assembly
(3) and remove power control cable assembly (3) from cable connector
bracket (9).
Discard lock washers (8).
Remove flat washer (10) and nut (11) from end of power control cable
assembly (3).
Remove three nuts (12), lock washers (13), three cable clamp mounting bolts
(14), and three cable clamps (15).
D i s c a r d l o c k w a s h e r s ( 1 3 ) . -
2.15.8.2 Installation.
Do not tighten cable clamps securely until power control cable assembly has
been adjusted.
a.
Install power control cable assembly
with three cable clamp mounting bolts
(12).
b.
Install nut (11) and flat washer (10)
( 3 ) .
3) in three cable clamps (15) and secure
(14), new lock washers (13), and nuts
on end of power control cable assembly
2-126
TM 10-4320-344-24