TM 10-4320-318-14
Section III. OPERATION UNDER USUAL CONDITIONS
2-6. Assembly and Preparation for Use. Refer to system manual for site requirements.
a.
Pump Unit Setup. Perform the following:
(1)
(2)
(3)
(4)
Remove the plastic caps from suction and discharge lines.
Retain caps for preparation for
movement.
NOTE
The anti-seizing tape is to be wrapped in the same direction as the pipe
threads.
Apply anti-seizing tape (Item 11, Appendix E) to pipe threads of pipe nipples. Install pipe nipples
to pump suction and discharge ports.
Install quick-disconnect coupling halves to pipe nipples. Refer to system manual.
WARNING
DO NOT operate engine around open fuel. Fuel presents an extreme explosion and fire
hazard. Make sure fuel lines are securely connected and free of leaks. Never refuel a
hot or running engine. Avoid overfilling fuel tank. Always use correct fuel type.
CAUTION
DO NOT operate pump unless casing is filled to top of suction port. Operating a dry
pump will cause overheating and damage to pump unit.
Remove priming plug (1, Figure 2-2) and fill pump casing with water to the top of the suction port
(2).
Figure 2-2. Primary Plug