2-48. MAINTENANCE OF OIL BREATHER ASSEMBLY
This task covers:
a.
Remove
b.
Install
INITIAL
SETUP
Tools
Equipment
Conditions
General Mechanics Tool Kit
Pumping assembly is shutdown (refer to TM 10-4320-
(Item 1, Appendix B)
315-10).
Battery assembly is disconnected (para. 2-16).
Parts/Materials
Sealant (item 15, Appendix C)
a.
REMOVE
. (Figure 2-35)
(1)
Remove capscrews (1), flat washers (2), and
muffler
access plate (3).
(2)
Remove mounting bolt (4), and flat washer (5), oil breather assembly (6), and bracket (7).
(3)
Remove bolt (8), flat washer (9), and hose retaining bracket (10) from hose (11).
(4)
If necessary,
remove hose
clamp (12). Remove hose (13) from oil breather assembly (6).
Figure 2-35. Oil Breather Assembly
2-90