3-13. MAINTENANCE OF NOISE ENCLOSURE BATTERY ACCESS PANEL
This task covers:
a.
Remove
b.
Install
INITIAL
SETUP:
Tools
Equipment
Conditions
General Mechanics Tool Kit
Roof removed (para. 3-7).
(Item 1, Appendix B)
Materials/Parts
Rivets (TM 10-4320-315-24P)
Lockwashers (TM 4320-315-24P)
a.
REMOVE,
(Figure 3-8)
(1)
Remove rivets (1) (para. 3-6).
(2)
Remove battery access hinged panel (2).
(3)
Remove nuts (3), flat washers (4), bolts (5), and flat washers (6).
(4)
Remove bolts (7) and flat washers (8).
(5)
Remove bolts
(9), flat washers (10), and panel (11).
(6)
Remove bolts
(12), flat washers (13), nuts (14), lockwashers (15), and mounting bracket (16).
b.
INSTALL
.
(1)
Install mounting bracket (16) with flat washers (13), bolts (12),
lockwashers
(15), and nuts (14).
(2)
Install panel (11) in mounting bracket (16) and secure with flat washers (10) and bolts (9).
(3)
Install bolts (7) and flat washers (8).
(4)
Secure panel (11) to interior brace with flat washers (6), bolts (5), flat washers (4), and nuts (3).
(5)
Install battery access hinged panel (2) with rivets (1) (para. 3-6).
3-21