TM 10-4320-310-14
2-4.
OPERATING PROCEDURE (Continued)
CAUTION
If housing does not fill with flammable liquid, check suction
hose and suction hose connection at suction (intake) coupling
for leaks. Be sure that suction hose end Is completely
Immersed in flammable liquid.
(3) Install pipe plug (1) in priming port and tighten securely.
c.
Starting.
CAUTION
If engine does not start on Initial attempt, allow engine rotation
to stop completely before engaging crank handle. Prime the
pump. Rotation of pump Impeller without flammable fluid In
housing can reduce service life of pump.
(1) Engage crank handle (1) in gear housing (2).
(2) Turn crank handle (1) clockwise with increasing speed.
(3) When decompression lever (3) reaches 0 position, the highest possible speed must be obtained. Engine
will start and go to maximum operating speed. Extra fuel device button (4) will return to normal position
by itself.
2-26