TM 10-4320-310-142-4.OPERATING PROCEDURE (Continued)CAUTIONIf housing does not fill with flammable liquid, check suctionhose and suction hose connection at suction (intake) couplingfor leaks. Be sure that suction hose end Is completelyImmersed in flammable liquid.(3) Install pipe plug (1) in priming port and tighten securely.c.Starting.CAUTIONIf engine does not start on Initial attempt, allow engine rotationto stop completely before engaging crank handle. Prime thepump. Rotation of pump Impeller without flammable fluid Inhousing can reduce service life of pump.(1) Engage crank handle (1) in gear housing (2).(2) Turn crank handle (1) clockwise with increasing speed.(3) When decompression lever (3) reaches 0 position, the highest possible speed must be obtained. Enginewill start and go to maximum operating speed. Extra fuel device button (4) will return to normal positionby itself.2-26