TM 10-4320-310-14
2-4.
OPERATING PROCEDURE (Continued)
(4) If pump is to be removed from system, remove pipe plug (1) and drain pump Into a suitable container.
(5) Remove suction hose from suction (intake) female coupling (2).
(6) Remove discharge hose from discharge male coupling (3).
(7) Cover suction (intake) female coupling (2) with dust plug (4).
(8) Cover discharge male coupling (3) with dust cap (5)
2-5.
IDENTIFICATION AND WARNING
PLATES
The centrifugal pump unit has the following identification and warning plates:
a.
Identification plate. Located on the left hand mounting bracket. Provides the pump model number, serial
number, dimensions, weight, and shipping information.
PUMP ASSEMBLY, FLAMMABLE LIQUID
NSN NO.
CONTRACT NO.
FSCM NO.
13646
DWG NO.
WEIGHT
LBS
S/N
SCOT DIV. ARDOX CORP. CEDARBURG, WI 53012
117.000.549
2-28