TM 10-4320-310-142-3.ASSEMBLY AND PREPARATION FOR USE (Continued)(8) Connect clamp and ground cable to ground rod and securely tighten screw.c.Perform category B (before operation) PMCS contained in Table 2-2 or verify that category B PMCS wasperformed. Report any problems to unit maintenance.d.The following paragraphs contain instructions for starting, operating and stopping the unit.2-4.OPERATING PROCEDURECARBON MONOXIDE (EXHAUST GAS) CAN KILL YOUExposure to exhaust gases produces symptoms of headache,dizziness, loss of muscular control, drowsiness, or coma.Brain damage or death can result from severe exposure.Fumes from engine become concentrated with poorventilation. Operate engine in a ventilated area only.While running engine, be alert for fumes. Keep areaventilated. If someone Is overcome, expose to fresh air;keep warm and still; give artificial respiration If needed. Seekmedical attention. Administer oxygen, if available.GOOD VENTILATION IS THE BEST DEFENSE AGAINSTEXHAUST POISONING.a.Preparation for starting.(1) Move throttle control hand lever (1)fully to left past stop (2).(2) Pull out extra fuel device button (3)until fully extended.(3) Turn decompression lever (4) clockwiseto 12 o'clock position (position 2).Ifdecompression lever is in the 6 o'clockposition, hand cranking will be extremelydifficult.2-24
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business