TM 10-4320-226-144.13.5 Oil Pressure (M1), Ammeter (M2), and Tachometer/Hourmeter (M3) Replacement.This task covers:4.13 .5.1 Removal4.13 .5.2 InstallationINITIALSETUPToolsGeneral Mechanic’s Tool Kit (appendix B,EquipmentConditions(continued)Control Panel Assembly Cover removed,Section III, Item 1)Materials/PartsTags (appendix E, Section II,EquipmentConditionsEquipment shut down, refer toparagraph 2.5.1.2 or 2.5.2.2.paragraph 4.13.1.GeneralSafety InstructionsItem 12)To prevent rolling or sliding, do notwork on equipment that is not securelystabilized.Do not work on equipment withoutfollowing standard shop safetyprecautions.Figure 4-45.Oil Pressure, Ammeter, and Tachometer/Hourmeter Replacement.4.13.5.1 Removal.To prevent rolling or sliding, do not work on equipment that is notsecurely stabilized.Ensure both wheels are secure.Failure to obey thiswarning may result in serious personal injury.a.Tag and disconnect wires (figure 4-45, 1) from gauge (2).b.Remove two nuts (3), lockwashers (4), and retaining bracket (5) from gauge atback of control panel.c.Remove gauge (2) from front of control panel.4.13.5.2 Installation.a.Installb.Installpanel.4-86gauge (2) through front of control panel.retainer bracket (5) and lockwashers (4) on gauge at back of control