TM 10-4320-226-144.13.4 011 Pressure Bypass (S2) and Push to Start (S3) Switch Replacement.This task covers:4.13.4.1 Removal4.13.4.2 InstallationINITIALSETUPToolsEquipmentConditions(continued)General Mechanic’s Tool Kit (appendix B,Control Panel Assembly Cover removed,Section III, Item 1)paragraph 4.13.1.Materials/PartsGeneralSafety InstructionsTags (appendix E, Section II, Item 12)To prevent rolling or sliding, do notwork on equipment that is not securelyEquipment Conditionsstabilized.Equipment shut down, refer toDo not work on equipment withoutparagraph 2.5.1.2 or 2.5.2.2.following standard shop safetyprecautions.Figure 4-44.Oil Pressure Bypass and Push to Start Switch Replacement.4.13.4.1 Removal.To prevent rolling or sliding, do not work on equipment that is notsecurely stabilized.Ensure both wheels are secure.Disconnect negative cables from batteries.Failure to obey this warning may result in serious personal injury.a.Tag and disconnect wires (figure 4-44, 1) from switch (2).b.Unscrew boot (3) from switch (2).c.Remove nut (4) from switch (2).d.Remove switch (2).4.13.4.2 Installation.a.Install switch (2).b.Install nut (4) on switch (2).c.Thread boot (3) on switch (2).d.Connect wires (1) on switch (2) and remove tags.4-85