TM 10-4320-226-144.13.3 Emergency Stop Switch (S1) Replacement.This task covers:4.13.3.1 Removal4.13.3.2 InstallationINITIALSETUPToolsGeneral Mechanic’s Tool Kit (appendix B,Section III, Item 1)Materials/PartsTags (appendix E, Section II, Item 12)Equipment ConditionsEquipment shut down, refer toparagraph 2.5.1.2 or 2.5.2.2.EquipmentConditions(continued)Control Panel Cover removed,paragraph 4.13.1.GeneralSafety InstructionsTo prevent rolling or sliding, do notwork on equipment that is not securelystabilized. -DO not work on equipment withoutfollowing standard shop safetyPrecautions.Figure 4-43.Emergency Stop Switch S1 Removal and Installation.4.13.3.1 Removal.To prevent rolling or sliding, do not work on equipment that is notsecurely stabilized.Ensure both wheels are secure.Disconnect negative cables from batteries.Failure to obey these warnings may result in serious personal injury.a.Disconnect negative battery cable.b.Tag and disconnect wires (figure 4-43, 1) from switch (2).c.Unscrew knob (3) from shaft.d.Remove nut (4)e.Remove switch4.13.3.2 Installation.a.Install switchfrom switch (2).(2) from control panel.(2) into control panel.4-83