TM 10-4930-204-13
4-24. ENGINE.
a. General. The following paragraphs contain the organizational maintenance instructions necessary for various
components associated with the engine.
b. Starter Pulley.
(1) Removal. Loosen pulley hub with suitable wrench and turn pulley counterclockwise to remove (fig. 4-9).
(2) Cleaning and inspection.
WARNING
(a)
(b)
Drycleaning solvent normally has a flash point of either 100 or
138 degrees F, depending on the type being used, but may
flash at much lower temperatures if contaminated with gasoline
or jet fuel. Avoid repeated and prolonged skin contact. Do not
use near open flame or excessive heat.
Clean all parts with drycleaning solvent (item 1, App. F), and dry thoroughly.
Inspect all parts for cracks, breaks, damaged threads, and other defects. Replace a damaged part.
(3) Installation. Position starter pulley and turn clockwise to install (fig. 4-9). Secure pulley by tightening hub
with a suitable wrench.
Change
4
4-28.1/(4-28.2
Blank)