TM 10-4930-204-13
Figure 4-9.
Starter Pulley, Air Shroud, and Ignition Switch Bracket,
Removal and Installation.
c.
Air Shroud.
(1) Removal.
(a) Remove
(b) Remove
starter pulley (para 4-24b.).
three bolts and ignition switch and bracket
from top of air shroud (fig. 4-9).
(c) Remove two bolts that secure air shroud to engine
base; remove shroud.
(2) Cleaning and inspection.
Drycleaning solvent normally has a flash point
of either 100 or 138 degrees F, depending on the
type being used, but may flash at much lower tem-
peratures if contaminated with gasoline or jet
fuel .
Avoid repeated and prolonged skin contact.
Do not use near open flame or excessive heat.
4-29