TM5-4930-230-13Table 4-2. Organizational Maintenance Troubleshooting — ContinuedMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION5. ELECTRIC MOTOR WILL NOT OPERATE.Step 1.Check vehicle power supply.Insure vehicle batteries and charging system are operating properly.Step 2. Check power cables.Test for continuity of Intervehicle cable and ON-OFF switch cable.4-32.)6. PUMP WILL NOT PUMP FUEL AT RATED CAPACITY.Step 1.Check for low pump engine speed.(Paragraph 4-31 andAdjust engine speed. (GED) Check truck engine RPM for proper charge rate. (EMD)Step 2. Check level in 600 gal fuel tanks.Fill tanks if empty.Step 3. Check that tank cam lever is fully open. Opencam lever.4-10