TM 5-4320-302-14
5-5. BEARING HOUSING ASSEMBLY (CONT)
Location/Item
Action
Remarks
CLEANING/INSPECTION
WARNING
Dry cleaning solvent is flammable and potentially dangerous
to people and property. Do not use near open flame, sparks,
excessive heat, or on hot surfaces. Flash point of P-D-680
solvent is 100° to 138°F (38 to 59 C). Use solvent in a
well-ventilated area, and avoid inhaling fumes. If repeatedly
exposed to fumes, seek fresh air and immediate medical
help. Avoid prolonged exposure of skin to solvent. Wash
exposed skin immediately and thoroughly.
Death or severe injury might result when compressed air is
used to blow dirt from skin or clothing. Air entering body
openings is extremely dangerous. Compressed air used for
cleaning shall not exceed 100 psi (690 kPa). Use goggles or
face shield for eye protection. Do not direct airstream against
skin.
8. Bearing housing
Clean with P-D-680 dry cleaning solvent and
assembly metal
dry with compressed air.
components
9. Bearing housing
Inspect for cracks, rust, corrosion, or other dam-
age. Inspect both engine and pump end mounting
surfaces. Make sure they are smooth and flat. In-
spect for excessive wear around mounting holes
and main bore. Repair rust or corrosion in accord-
ance with MIL-T-704. Clean and treat interior or
mounting surfaces. Clean, treat, and refinish out-
side surface. If unit is severely damaged, cracked,
or worn, replace unit.
10. Bearing cap
Inspect for excessive wear, rust, corrosion, or
other damage. Replace if worn or damaged.
WARNING
Do not rotate bearings with compressed air.
11. Bearings
Inspect bearings for rough or tight spots. Replace
bearings if rough or tight. Inspect bearing ex-
terior for rust, corrosion, or other damage. Re-
place bearings if damaged.
5-18