TM 5-4320-302-145-5. BEARING HOUSING ASSEMBLY (CONT)Location/ItemActionRemarksCLEANING/INSPECTIONWARNINGDry cleaning solvent is flammable and potentially dangerousto people and property. Do not use near open flame, sparks,excessive heat, or on hot surfaces. Flash point of P-D-680solvent is 100° to 138°F (38 to 59 C). Use solvent in awell-ventilated area, and avoid inhaling fumes. If repeatedlyexposed to fumes, seek fresh air and immediate medicalhelp. Avoid prolonged exposure of skin to solvent. Washexposed skin immediately and thoroughly.Death or severe injury might result when compressed air isused to blow dirt from skin or clothing. Air entering bodyopenings is extremely dangerous. Compressed air used forcleaning shall not exceed 100 psi (690 kPa). Use goggles orface shield for eye protection. Do not direct airstream againstskin.8. Bearing housingClean with P-D-680 dry cleaning solvent andassembly metaldry with compressed air.components9. Bearing housingInspect for cracks, rust, corrosion, or other dam-age. Inspect both engine and pump end mountingsurfaces. Make sure they are smooth and flat. In-spect for excessive wear around mounting holesand main bore. Repair rust or corrosion in accord-ance with MIL-T-704. Clean and treat interior ormounting surfaces. Clean, treat, and refinish out-side surface. If unit is severely damaged, cracked,or worn, replace unit.10. Bearing capInspect for excessive wear, rust, corrosion, orother damage. Replace if worn or damaged.WARNINGDo not rotate bearings with compressed air.11. BearingsInspect bearings for rough or tight spots. Replacebearings if rough or tight. Inspect bearing ex-terior for rust, corrosion, or other damage. Re-place bearings if damaged.5-18
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business