TM 5-4320-302-14
WARNING
Priming discharge mixture of water and exhaust gases may
cause severe burns or injury. Wear gloves and safety glasses
when priming pump.
Stand clear of venturi during priming.
CAUTION
Prime the centrifugal pump as soon as possible after engine
starts. Rotation of impeller without water in volute will
damage pump components.
f. Start engine and allow to operate at 2800 rpm for not less than 5 minutes. Shut down engine.
g. Service air cleaner primary and secondary elements in accordance with table 2-2, item 15.
h. Remove pump drain plug and drain pump body. Replace drain plug.
i. Remove suction hose from suction flange (intake).
4-185