TM 5-4320-302-14WARNINGDry cleaning solvent is flammable and potentially dangerousto people and property. Do not use near open flame,sparks, excessive heat, or on hot surfaces. Flash point ofP-D-680 solvent is 100° to 138°F (38 to 59°C). Use sol-vent in a well-ventilated area, and avoid inhaling fumes. Ifrepeatedly exposed to fumes, seek fresh air and immediatemedical help. Avoid prolonged exposure of skin to solvent.Wash exposed skin immediately and thoroughly.p. Inspect exterior of centrifugal pump unit for damaged paint. Refinish in accordance withMilitary Specification MIL-T-704, Type A, color as specified.q. Remove and clean battery in accordance with table 4-1, item 5.4-43. SHIPMENTa. Use shipping plugs, closures, or sealing tape to cover all openings in the pump assembly.b. Attach to the pump assembly all forms, tags, and records applicable to the unit.WARNINGAvoid making contact across the two battery posts. Thiscan result in severe arcing which could cause an explosionresulting in bodily injury.CAUTIONDisconnect battery cable from ground battery post beforedisconnecting any other leads from engine components.This precaution will prevent short circuits which coulddamage the alternator, voltage regulator, or other electricalcomponents.When removing battery cable, use battery terminal puller toremove loosened terminals. Forcing battery terminals offwithout using puller may damage the battery posts.Never disconnect battery while alternator is operating.Never attempt to polarize the alternator.c. Disconnect battery cables in accordance with table 4-1, item 5. Tape the battery cables to pre-vent contact with battery terminals. Replace battery box cover.4-187