TM 5-4320-302-14
WARNING
Dry cleaning solvent is flammable and potentially dangerous
to people and property. Do not use near open flame,
sparks, excessive heat, or on hot surfaces. Flash point of
P-D-680 solvent is 100° to 138°F (38 to 59°C). Use sol-
vent in a well-ventilated area, and avoid inhaling fumes. If
repeatedly exposed to fumes, seek fresh air and immediate
medical help. Avoid prolonged exposure of skin to solvent.
Wash exposed skin immediately and thoroughly.
p. Inspect exterior of centrifugal pump unit for damaged paint. Refinish in accordance with
Military Specification MIL-T-704, Type A, color as specified.
q. Remove and clean battery in accordance with table 4-1, item 5.
4-43. SHIPMENT
a. Use shipping plugs, closures, or sealing tape to cover all openings in the pump assembly.
b. Attach to the pump assembly all forms, tags, and records applicable to the unit.
WARNING
Avoid making contact across the two battery posts. This
can result in severe arcing which could cause an explosion
resulting in bodily injury.
CAUTION
Disconnect battery cable from ground battery post before
disconnecting any other leads from engine components.
This precaution will prevent short circuits which could
damage the alternator, voltage regulator, or other electrical
components.
When removing battery cable, use battery terminal puller to
remove loosened terminals. Forcing battery terminals off
without using puller may damage the battery posts.
Never disconnect battery while alternator is operating.
Never attempt to polarize the alternator.
c. Disconnect battery cables in accordance with table 4-1, item 5. Tape the battery cables to pre-
vent contact with battery terminals. Replace battery box cover.
4-187