TM 5-4320-302-14Table 4-2. Organizational Maintenance Troubleshooting - ContinuedMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONStep 2. Check V-belts for breaks or damage. Check tension of belts.Tighten or replace V-belts as necessary (para 4-26 and 4-27).Step 3. Check exhaust system foran obstruction or dam-aged exhaust primerassembly.Remove obstruction,free-up, and lubri-cate exhaust valvewith MIL-L-2104lubricating oil; orreplace exhaustprimer assembly(para 4-18).Step 4. Notify direct support.6. LOW ENGINE OIL PRESSUREWARNINGPriming discharge mixture of water and ex-haust gases may cause severe burns or injury.Wear gloves and safety glasses when primingpump.* Stand clear of venturi during priming.Prime the centrifugal pump as soon as possibleafter engine starts. Rotation of impeller withoutwater in volute will damage pump components.Step 1. Shut down engine and check oil system for leaks. Check for damaged andleaking oil lines and fittings. Check inside control panel cover assembly forevidence of leakage from oil pressure switchgage or oil pressure line hose. Check4-41
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business