TM 5-4320-300-146-13. WATER PUMP (CONT)Location/ItemActionRemarksREASSEMBLY14. Pump bodyPosition with cover side down on a solid blockof wood.CAUTIONBearing damage may occur if pump is assembled by pushing on. end of pump shaft.15. Bearing andPosition at opening on top of pump body.shaftApply pressure to outer bearing race untilassemblyit is flush with outer face of pump body.16. Seal assemblyLightly coat outside diameter of new sealProperly installedassembly with MIL-S-45180 sealing compound.flange should con-Support face of body and outer race of bearing.tact pump body.Apply pressure to seal outer flange and installseal assembly. Remove dirt and metal particlesfrom face of seal with lint-free cloth.17. ImpellerPosition pulley end of shaft on bed of an arborpress. Push impeller on shaft until impeller isflush with cover end of pump body.6-123