TM 5-4320-300-146-9. VALVES, CAMSHAFT, AND TIMING GEARS (CONT)Location/ItemActionRemarksWARNINGDry cleaning solvent is flammable and potentially dangerous to people and property. Do not usenear open flame, sparks, excessive heat, or on hot sur- faces. Flash point of P-D-680 solvent is100° to 138° F (38° to 59°C). Use solvent in a well-ventilated area, and avoid inhaling fumes. Ifrepeatedly ex- posed to fumes, seek fresh air and immediate medical help. Avoid prolongedexposure of skin to solvent. Wash exposed skin immediately and thoroughly.Compressed air used for cleaning shall not exceed 100 psi (690 kPa). Use goggles or face shield for eye protection. Donot direct airstream against skin.35. Valve seatClean seat inserts with P-D-680 dryinsert andcleaning solvent and dry with com-counterborepressed air. Inspect counterbores forcleaning andcleanliness, roundness, and flatness;inspectioninspect for cracks and other damage.36. Valve seatIf counterbores are clean, round, flat and un-insert in-damaged, immerse the cylinder head for 30stallationminutes in water heated to 180° to 200°F(82° to 93°C).CAUTIONDamage to valve insert may result if insert is installed after the cylinder head has cooled. Installvalve seat inserts immediately after removing head from water bath.Remove cylinder head from water bath and rest it bottom side up on a bench. Place an insert in the counterbore valveseat side up. This must be done quickly while cylinder head is still hot and insert is cold (room temperature). Drive insertin place until it seats solidly in the cylinder head.6-68