TM 5-3825-270-23&P
0121
CLEANING/INSPECTION - Continued
WARNING
Compressed air used for cleaning and drying purposes must not exceed 30 psi (207 kPa).
Use only with effective chip guarding and proper protective equipment (goggles, shield,
gloves, etc.). Failure to comply may result in injury or death to personnel.
2.
Blow parts dry.
3.
Inspect mating surfaces for cracks, burrs, or pitting.
END OF TASK
INSTALLATION
1.
Apply -inch bead of silicone sealant (Figure 2, Item 5) to oil pan mating surface (Figure 2, Item 6).
6
5
Figure 2. Oil Pan Sealant Application.
2.
Install oil pan (Figure 3, Item 4) on engine block (Figure 3, Item 3) with four screws (Figure 3, Item 1). Tighten
screws finger tight.
1
2, 3
4
Figure 3. Oil Pan Installation.