Figure 2. 15-amp Circuit Breaker Removal.
Figure 6. 15-amp Circuit Breaker Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  456    457    458    459    460  461  462    463    464    465    466  
img
.
TM 5-3825-270-23&P
0078
REMOVAL - Continued
5
12
9, 13
Figure 4. 15-amp Circuit Breaker Removal.
NOTE
Note position of 15-amp circuit breaker prior to removal to ensure proper installation.
6.
Remove nut (Figure 4, Item 12) and 15-amp circuit breaker (Figure 4, Item 9) from main control box (Figure
4, Item 5).
END OF TASK
INSTALLATION
NOTE
Install 15-amp circuit breaker as noted prior to removal.
1.
Install 15-amp breaker (Figure 5, Item 9) on control box (Figure 5, Item 5) with nut (Figure 5, Item 12).
5
12
9, 13
Figure 5. 15-amp Circuit Breaker Installation.
2.
Install protective cover (Figure 5, Item 13) on 15-amp circuit breaker (Figure 5, Item 9).