Figure 7. Gauge Harness Connector - Step 4.
Figure 11. Engine Temperature Gauge - Step 6.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  195    196    197    198    199  200  201    202    203    204    205  
img
.
TM 5-3825-270-23&P
0036
STEP 5
Are less than 200 ohms measured from ENGINE TEMP gauge harness connector, pin 3 to interconnect
harness connector, terminal 19?
1.
Ensure multimeter is set to measure continuity.
2.
Connect red multimeter probe to ENGINE TEMP gauge harness connector, pin 3.
GAUGE
HARNESS
CONNECTOR
1
2
3
4
5
6
BACK OF
CONTROL PANEL
Figure 9. Gauge Harness Connector - Step 5.
3.
Connect black multimeter probe to interconnect terminal strip, terminal 19.
INSIDE OF
15-AMP
CONTROL PANEL
CIRCUIT BREAKER
20
1
1
15
5
5
EMERGENCY
10
10
10
STOP SWITCH
5
15
15
1
20
20
POSITIVE
NEGATIVE
INTERCONNECT
TERMINAL STRIP
TERMINAL STRIP
TERMINAL STRIP
Figure 10. Interconnect Terminal Strip - Step 5.
4.
Note multimeter reading.
CONDITION/INDICATION
Are less than 200 ohms measured from ENGINE TEMP gauge harness connector, pin 3 to interconnect harness
connector, terminal 19?
0036-7