Figure 2. Preparation For Dust Control Agent Use.
Figure 4. Preparation For Dust Control Agent Use.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
img
.
TM 5-3825-270-10
0010
PREPARATION FOR DUST CONTROL AGENT USE - Continued
10 12
10
8, 9
6
2
11
Figure 3. Preparation For Dust Control Agent Use.
8.
Remove cap (Figure 3, Item 11) from suction hose (Figure 3, Item 2).
9.
Attach suction hose (Figure 3, Item 2) to 3" coupling cam (Figure 3, Item 6).
10.
Remove cap (Figure 3, Item 12) from tote (Figure 3, Item 10).
11.
Open valve V1 (Figure 4, Item 13).
0010-4