Figure 13. APU Hydraulic Oil Hoses.
Figure 15. APU Emergency Stop Button.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  428    429    430    431    432  433  434    435    436    437    438  
img
.
TM 5-3820-276-10-2
0200
Table 4.
PMCS - MCS - Before Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
WWDS00957
Figure 14. Grounding Reel.
NOTE
3
Before
APU Emergency
Stop Button
APU Emergency Stop Button is used to
stop electrical power output from APU only.
It's use will not stop MCS engine or
hydraulic pressure.
Check that APU Emergency Stop Button (Figure 15,
APU Emergency Stop
Item 1) is reset (pulled out).
Button will not reset.
Notify maintenance.