• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. AC Receptacles.
HIGH POWER OUTPUT AT AC RECEPTACLES - WELDER/GENERATOR

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  222    223    224    225    226  227  228    229    230    231    232  
img
. .
TM 5-3820-276-10-2
0155
OPERATOR MAINTENANCE
LOW POWER OUTPUT AT AC RECEPTACLES - WELDER/GENERATOR
INITIAL SETUP:
Equipment Condition
Engine off (Volume 1, WP 0045)
TROUBLESHOOTING PROCEDURE
LOW POWER OUTPUT AT AC RECEPTACLES - WELDER/GENERATOR
SYMPTOM
Low power output at AC receptacles.
MALFUNCTION
Fine control switch not properly set.
CORRECTIVE ACTION
Verify if fine control switch is set to 10 (Figure 1).
FINE CONTROL SWITCH
WWDS00470
Figure 1.
Fine Control Switch.
a.
If not set to 10, position fine control switch to 10. Verify if proper power is present at AC
receptacles (Volume 1, WP 0045).
b.
If fine control switch is set to 10, notify maintenance.
END OF WORK PACKAGE
0155-1/blank
02/13/2013root(tswp)wpno(T20036)