LOW OR NO WELD OUTPUT AND GENERATOR POWER OUTPUT OKAY AT AC RECEPTACLES - WELDER/GENERATOR
Figure 2. Grounding Clamp.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  211    212    213    214    215  216  217    218    219    220    221  
img
.
TM 5-3820-276-10-2
0149
LOW OR NO WELD OUTPUT AND GENERATOR POWER OUTPUT OKAY AT AC RECEPTACLES -
WELDER/GENERATOR - Continued
CORRECTIVE ACTION - Continued
MALFUNCTION
Insufficient welding connections.
CORRECTIVE ACTION
Verify welding cables (Figure 1) are tight on welder/generator (Volume 1, WP 0044).
WORK
ELECTRODE
CONNECTION
CONNECTION
WWDS00465
Figure 1.
Welding Cable Connection.
a.
If cables are tight, proceed to next MALFUNCTION - Insufficient ground clamp connection.
b.
If cables are not tight, tighten cable connections (Volume 1, WP 0044).
MALFUNCTION
Insufficient ground clamp connection.
CORRECTIVE ACTION
Verify grounding clamp is properly connected to work piece (Figure 2).