TM 10-4930-236-13&POPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICESB - BeforeD - DuringA - AfterW - WeeklyM - MonthlyINTERVALPROCEDURESEQUIPMNET ISITEMITEM TO BECHECK FOR AND HAVE REPAIREDNOT READY/NOBD AWMINSPECTEDOR ADJUST AS NECESSARYAVAILABLE IF:WARNINGA spring loaded mechanism can causeinjury if released in an uncontrolled manner.The rewind spring is under high tensionwhen the ground cable is extended. Thismay cause reel to rapidly rotate in reverse.4***StaticCheck for broken clamp, cable or cableBroken cable,Dischargecoating. Refer to next higher level ofcoating orReelmaintenance for repairs.clamp thatwould notallow a properground.5***Filter/SeparatorRefer to TM5-4330-232-12&P forWater Detectorprocedures to inspect filter/separator.Kit6***EMD PumpCheck pump and components for properEvidence ofoperation, damage or leakage. Notifyfuel leakage.next higher level of maintenance forrepair.WARNINGLow voltage can cause Severe Shock orDeath. Disconnect power cable fromvehicle NATO slave receptacle beforereplacing or repairing electrical components.7**Junction BoxCheck for damaged cables, looseDamagedconnections, switch, or connectors.connectors,Check junction box for defective coverswitch cablesseal. Tighten connections if required.(that couldcause sparks),Notify next higher level of maintenanceor cover seal.for repair.2-9