TM 10-93-23-1 3&PTable 2-1. Controls and Indicators - CONTCONTROL ORKEYINDICATORFUNCTION12aPump Motor ON-OFFSwitch/Cable AssemblyThe switch is located at the end of the operator control cableThe ON position applies power to the electric motor to operatethe pump. The OFF position stops the motor12bAuxiliary Pump MotorON-OFF SwitchThis switch operates the same as Item 12, however, thisswitch attaches directly to the electrical junction box13Suction Loading CouplingThis coupling is installed for bottom loading of the fuel tanksfrom a non-pressurized fuel source. The pump assembly onboard the truck is used to fill the fuel tanks.14DipstickThe dipstick is graduated in US GALLONS on one side, andLITERS on the other. It is used to measure the quantity of fuelin the tanks through DIPSTICK/HAND PUMP access pump.SECTION II. OPERATOR'S PREVENTIVE MAINTENANCE CHECKSAND SERVICES (PMCS)ParagraphPage2-3General ...............................................................................................2-52-4Purpose of PMCS Tablle .....................................................................2-62-5Explanation of Columns .......................................................................2-62-6Equipment is Not Ready If Column ......................................................2-62-7Reporting Deficiencies .........................................................................2-62-8Special Instructions ..............................................................................2-62-3.General.Operator PMCS are performed to ensure that the tank and pump unit is ready for operation atall times. Perform the checks and services at the specified intervals.a.Before you operate, perform your before (B) PMCS. Observe all CAUTIONS and WARNINGS.b.While you operate, perform your during (D) PMCS. Observe all CAUTIONS and WARNINGS.2-5
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business