TM 10-4930-236-13&PDISASSEMBLYWARNINGDry cleaning solvent, P-D-680, used to clean parts is potentiallydangerous to personnel and property. Avoid repeated andprolonged skin contact. Do not use near open flame orexcessive heat. Flash point of solvent is 100 degrees F-138degrees F (38 degrees C-59 degrees C).NOTEDiscard all mandatory replacement parts.a.Fill cover.(1)Thoroughly clean the exterior of the manhole assembly with dry cleaning solvent.(2)Open cam (8).(3)Remove washer nuts (9), hinge pin (10) and fill cover assembly (11).(4)Remove nut (12), washer (13), capscrew (14), spacer (15) and hinge (16).(5)Remove nut (17), fuse plug (18) and gasket (19).(6)Remove nut (20), vent (21) and gasket (22).(7)Separate plug (23) from gasket retainer (24) and remove gasket (25).4-56