TM 10-4930-204-13
(2) Cleaning and inspection.
Drycleaning solvent normally has a flash point
of either 100 or 138 degrees F, depending on the
type being used, but may flash at much lower tem-
peratures if contaminated with gasoline or jet
fuel .
Avoid repeated and prolonged skin contact.
Do not use near open flame or excessive heat.
(a) Clean all parts with drycleaning solvent, (item
App . F), and dry thoroughly.
(b) Inspect carburetor for cracks, breaks, loose or
missing screws, damaged bowl gasket, or other damage.
place damaged
carburetor.
(3)
carburetor.
(4)
4-17).
carburetor.
(5)
carburetor.
1,
(c) Tighten or replace loose or missing screws. Re-
or defective bowl gasket.
Replace damaged or defective
Service.
Refer to figure 4-18 and service the
Installation.
(a) Install carburetor and secure with two nuts (fig.
(b) Connect governor control rod and fuel line to
(c)
Install the air cleaner (para 4-24h.).
Adjustment.
Refer to figure 4-19 and adjust the
j.
Governor Controls.
(1) Removal.
(a) Refer to figure 4-20 and
rod from carburetor and remove cotter pin to
control lever.
unscrew governor control
separate control rod and
(b) Remove nut securing governor control lever; unhook
spring, and detach governor control lever.
(c) Remove two nuts and adjusting screw.
(d) Remove cotter pin, support pin, and spring. Lift
speed control lever from speed control bracket.
4-39