TM 10-4630-207-13&P
0026 00
2. Fan belt
a. Ensure battery is disconnected at the negative terminal post.
b. Loosen and remove fan shroud (figure 16, item 1) mounting bolts (figure 16, item 2).
c.
Remove fan shroud (figure 16, item 1).
d. Loosen belt tension bolt (figure 17, item 1) on generator (figure 17, item 2).
e. Pivot generator towards water pump to slacken the fan belt (figure 18, item 1).
f.
Remove the fan belt (figure 18, item 1).
g. Install new fan belt (figure 18, item 1) on generator, fan and engine pulleys.
h. Pivot generator away from water pump, tightening fan belt tension (figure 17, item 1).
i.
Check the drive belt tension between the fan pulley (figure 19, item 1) and the generator pulley
(figure 19, item 2).
Ensure belt has -inch deflection at
the center between the two pulleys.
j.
Install fan shroud (figure 16, item 1).
k.
Install and tighten fan shroud mounting bolts (figure 16, item 2).
l.
Reconnect the battery at the negative terminal post.
1
2
2
1
Figure 16. Fan Shroud Mounting Bolts
Figure 17. Belt Tension Bolt
0026 00-11