TM 10-4630-206-12&P
0005 00
EQUIPMENT STORAGE AND SHIPMENT
Placement of Equipment in Storage. Storage should only be affected for short spans of time when a
shortage of maintenance effort exists. Items should be mission ready within 24-hours, or within time
factors set by directing authority. During storage periods, maintenance records must be kept.
Storage Site Selection. Covered space is preferred. When sufficient covered space is not available,
priority should be given to items that are most susceptible to deterioration from the elements. Open sites
should be improved hardstand, if available. Unimproved sites should be firm, well-drained locations, free
of excessive vegetation.
Preparation for Storage and Shipment. Before storing or shipping the SEP, current maintenance
services must be completed; defects and failures corrected; and Modification Work Orders (MWOs)
applied.
Inventory and Pack SEP
1. Verify that tank is empty.
2. Clean tank interior with chlorine solution let stand 1-hour.
3. Rinse tank interior with fresh water and drain.
4. Ensure that circuit breakers are set to OFF.
5. Disconnect all exterior hoses.
6. Disconnect power and wrap power cord around the tank assembly (9-1-0150-1 and 9-1-0150-2) or in
the recess around the control box (9-1-0527).
CAUTION
Ensure that the Circuit Breaker Box/Control Box is secured closed
before cleaning SEP exterior.
7. Clean SEP exterior by hosing it down with fresh-water (circuit breaker box/control box closed).
8. Using a pipe wrench or strap wrench, remove the PVC drain valve, nipple, and bushing (if fitted, 9-1-
0150-1 and 9-1-0150-2).
9. Using a pipe wrench or strap wrench, remove all QDC fittings from the tank assembly.
10. Thread the 3-IN. plugs hand tight into the open drain, inlet, and discharge ports.
11. Install the QDC fittings on the inside of the bushings (9-1-0527). Place the valve and fittings inside
the tank assembly (9-1-0150-1 and 9-1-0150-2). (Refer to Table 1, SEP Packing Inventory, for
inventory).
12. Re-install plug into drain port.
13. Ensure lid/access panel is installed securely.
0005 00-7