TM 10-4320-344-24
Some end panel assembly mounting screws are secured with nuts.
Mark location
of screw and nut combinations to facilitate reinstallation.
a.
Remove screws (Figure 2-22, 1) and nuts (2) from end panel assembly (3).
Mark
location of nut and screw combinations.
Two people are required to
assembly.
Failure to obey
damage to the equipment.
lift the end panel assembly from the pumping
this warning may result in personal injury or
b.
Remove end panel assembly (3) from pumping assembly (4).
2.12.11.2 Inspection.
Inspect end panel assembly for (3) for deterioration or damage
of insulation material on inner surface, corrosion, bends, or cracks.
2.12.11.3 Repair.
a.
Replace damaged or deteriorated insulation material on inner surface of end
panel assembly (3).
Refer to Appendix D to manufacture new insulation
material.
b .
Replace end panel assembly (3) if corroded or damaged to the extent that it
can not be properly mounted or secured.
2.12.11.4 Installation.
Two people are required to lift the end panel assembly onto the pumping
assembly.
Failure to obey this warning may result in personal injury or
damage to the equipment.
a.
Position end panel assembly (3) on pumping assembly (4).
Ensure screw and nut combinations are installed at locations marked during
removal.
b .
Install screws (1) and nuts (2), at locations marked during removal.
2-69