TM 10-4320-344-242.12.7 Control Panel Housing Assembly Maintenance, Model 609-C.This task covers:2.12.7.1 Removal2 .12 . 7 . 2 I n s t a l l a t i onINITIAL SETUPToolsEquipment Conditions (Continued)General Mechanic’s AutomotiveManual Throttle Control Cable removed,Tool Kit, Appendix B, SectionIII, Item 1paragraph 2.16.26.Auto Defeat Cable removed, paragraphEquipment Conditions2.16.28.Pumping station shut down, T M10-4320-344-10.Cold Start Aid Cable removed, paragraph2.16.29.Top Panel Assembly removed,General Safety Instructionsparagraph 2.12.4.To prevent rolling or sliding, do not workControl Panel Assembly removed,on equipment that is not securelyparagraph 2.15.3.s t a b i l i z e d.Do not work on equipment without followingstandard shop safety precautions.2.12.7.1 Removal.Some control panel housing assembly mounting bolts are secured with nuts.Mark location of bolt and nut combinations to facilitate reinstallation.a .Remove bolts (Figure 2-18,1) and nuts (2) from control panel housing assembly( 3 ).Mark location of screw and nut combinations.Figure 2-18.Control Panelb .Remove control panel housing assembly (3)Housing Assembly.from pumping assembly (4).2 - 6 0