TM 10-4320-344-24
2.16.7 Pump Suction and Discharge Gauge Assemblies Maintenance. Models 609-A and 609-C. (Continued)
Figure 2-58.
2.16.7.3 Installation.
Pump Suction and Discharge Gauge Maintenance, Model 609-A
Wrap antiseize tape in direction of threads on all pipe threads prior to
i n s t a l l a t i o n.
a.
Position pump suction gauge assembly (3) on mounting plate (10) and secure
with three new lock washers (9) and screws (8).
b .
Position pump suction gauge assembly (3) against control panel (7) and secure
with three spacers (6), new lock washers (5), and screws (4).
c .
Model 609-A only,
install new fluid pressure dampener (2) on pump suction
gauge assembly (3).
d.
Install elbow and hose assembly (1) on fluid pressure dampener (2).
2-156