TM 10-4320-344-242.16.7 PumpSuctionandDischargeGaugeAssembliesMaintenance.Models609-Aand609-C. (Continued)Figure 2-58.2.16.7.3 Installation.Pump Suction and Discharge Gauge Maintenance, Model 609-AWrap antiseize tape in direction of threads on all pipe threads prior toi n s t a l l a t i o n.a.Position pump suction gauge assembly (3) on mounting plate (10) and securewith three new lock washers (9) and screws (8).b .Position pump suction gauge assembly (3) against control panel (7) and securewith three spacers (6), new lock washers (5), and screws (4).c .Model 609-A only,install new fluid pressure dampener (2) on pump suctiongauge assembly (3).d.Install elbow and hose assembly (1) on fluid pressure dampener (2).2-156