2.16.6 Control Panel Assembly Hiring Maintenance, Models 609-C and US636HCCD-1.
This task covers:
2 .
16 . 6 . 1 T e st
2 .
16 . 6 . 2 R e p a ir
INITIAL SETUP
Tools
Equipment Conditions (Continued)
General Mechanics Automotive
Battery disconnected, paragraph 2.15.3 or
Tool Kit, Appendix B, Section
2 .
1
5 .
4.
III, Item 1
Control Panel Assembly Cover removed,
Multimeter, Appendix B, Section
paragraph 2.16.2, (US636HCCD-1).
III, Item 2
General Safety Instructions
Soldering Gun, Appendix B,
Section III, Item 2
To prevent rolling or sliding, do not work
on equipment that is not securely
Materials/Parts
s t a b i l i z e d.
Solder, Appendix C, Item 25
Do not work on equipment with battery
Straps, Electrical Tiedown,
connected.
Electrocution hazard is
Appendix C, Item 29
present if battery is connected.
Tags, Appendix C, Item 31
Do not work on equipment without following
Equipment Conditions
standard shop safety precautions.
Pumping station shut down, TM
10-4320-344-10.
Do not work on equipment with battery connected.
Electrocution hazard is
present if battery is connected.
Failure to obey this warning may result in
death or serious personal injury.
2.16.6.1 Test.
Using multimeter set for continuity, refer to Appendix F, as
a p p l i c a b l e , and check continuity of wires.
2.16.6.2 Repair.
If any wire does not give continuity, refer to Appendix D and repair
wiring harness as required.
2-154
TM 10-4320-344-24