TM 10-4320-344-242.15.4 Battery Box and Cover Maintenance. Model US63611HCCD-1.This task covers:2.15.4.1 Removal2 .15 . 4 . 2 I n s t a l l a t i o nINITIALSETUPToolsGeneral Mechanic’s AutomotiveTool Kit, Appendix B, SectionIII, Item 1Material/PartsGloves, Appendix C, Item 11Tags, Appendix C, Item 31Lock Washers (TM 10-4320-344-24P)Equipment ConditionsPumping station shut down, TM10-4320-344-10.PersonnelTwo people are required to lift thestorage battery.General Safety InstructionsTo prevent rolling or sliding, do not workon equipment that is not securelys t a b i l i z e d.Fumes from battery acid may cause explosion,which could result in personal injury. Keepsparks and open flame away from battery.B a t t e r y e l e c t r o l y t e c o n t a i n s s u l f u r i c a c i d,which can cause severe burns. Ifelectrolyte should contact skin or clothing,rinse immediately with clean water and seekmedical attention.Do not work on equipment without followingstandard shop safety precautions.2.15.4.1 Removal.a.Remove two nuts (Figure 2-40, 1), lock washers (2), and flat washers (3).Discard lock washers (2).Fumes from battery acid may cause explosion, which could result in personali n j u r y.Keep sparks and open flame away from battery.b .Remove battery box cover (4).Remove from battery cable first. Failure to obey this warning may resultin death or personnel injury.c .T a g p o s i t i v e ( + ) a n d n e g a t i v e ( - ) b a t t e r y c a b l e a s s e m b l i e s ( 6 ) . L o o s enbattery cable terminals (5) and remove two battery cable assemblies (6) withtwo grommets (7) from storage battery (8) and battery box (9).2-114
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business